Table 1 gives the BWEA Reference Annual Energy for the Aircon 10S. Table 2 shows the AEP estimations for hub height integer annual average wind speeds from 4m/s, up to the maximum wind speed for the turbine class II at sea level air density.
Reference Air Density: 1.225kg/m³
Cut Out Wind Speed: No cut out wind speed but extrapolation taken up to 25m/s
| extrapolated | measured | |||||
| Wind- Rayleigh distribution | Annual production |
Uncertainty of the measure |
Annual production |
Uncertainty of the measure |
||
| (standard deviation) | (standard deviation) | |||||
| [m/s] | [kWh] | [kWh] | % | [kWh] | [kWh] | % |
| 4 | 9065 | 880 | 9.7 | 9065 | 880 | 9.7 |
| 5 | 17488 | 1238 | 7.1 | 17488 | 1238 | 7.1 |
| 6 | 26714 | 1466 | 5.5 | 26714 | 1466 | 5.5 |
| 7 | 35599 | 1571 | 4.4 | 35599 | 1571 | 4.4 |
| 8 | 43549 | 1596 | 3.7 | 43549 | 1593 | 3.7 |
| 9 | 50307 | 1576 | 3.1 | 50307 | 1567 | 3.1 |
| 10 | 55731 | 1534 | 2.8 | 55731 | 1514 | 2.8 |
| 11 | 59788 | 1482 | 2.5 | 59788 | 1446 | 2.5 |